Loading ...
Loading ...
Loading ...
4
Assembly see page 32
Spare parts (see page 37)
Cleaning (see page 35) and en-
closed brochure
Flow diagram
(see page 36)
Rate of flow Normal spray with
EcoSmart
®
Rate of flow Normal spray without
EcoSmart
®
Handspray flow rate with EcoSmart
®
Handspray flow rate without EcoSmart
®
Dimensions (see page 36)
Operation (see page 31)
Do not rotate the spout further than 360º
or damage to the hose will result.
Hansgrohe recommends not to use as
drinking water the first half liter of water
drawn in the morning or after a pro-
longed period of non-use.
Adjustment (see page 34)
To adjust the hot water limiter. Using a hot
water limiter in combination with a continu-
ous flow water heater is not recommended.
Symbol description
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The hot and cold supplies must be of equal pres-
sures.
Installation Instructions
Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
The plumbing codes applicable in the respective
countries must be oberserved.
Technical Data
Operating pressure: max. 1 MPa
Recommended operating pressure: 0,1 - 0,5 MPa
Test pressure: 1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature: max. 70°C
Recommended hot water temp.: 65°C
Thermal disinfection: max. 70°C / 4 min
The product is exclusively designed for drinking water!
English
Do not use silicone containing acetic acid!
Test certificate (see page 40)
Maintenance (see page 35)
The check valves must be checked regularly
according to DIN EN 1717 in accordance
with national or regional regulations (at least
once a year).
Loading ...
Loading ...
Loading ...