Chapter 12 Serial Bus Trigger and Decode (Optional)
229
(1) Tap S1 to open the decode channel, and click again to open the bus configuration menu;
(2) Select the bus type as “LIN”, click “Ch1”, “Idle High”, “19.20kb/s”, and then close the menu;
(3) Open the trigger mode configuration menu and click “Sync-Rising”;
(4) Click configuration information to open the decode channel threshold level adjustment box, and drag
the adjustment box upward and downward to adjust the threshold level; adjust the threshold level according
to the signal amplitude level to make the signal stably triggered. The LIN trigger graphic interface is shown
in Figure 12-12: