228
Figure 12-11 LIN Trigger Mode Configuration Menu
a) Synchronous rising edge – When the “Sync Interval” of LIN bus ends, the rising edge triggers.
b) Frame ID — Triggered when a frame with an ID equal to the set value is detected. Select “Frame ID”, click
data on the touch screen, and use the pop-up virtual keyboard to modify it.
c) ID + data—triggered when a frame with ID and data equal to the set value is detected. After selecting
“Frame ID and Data”, click ID or data, and set them.
LIN serial decode
Ch1 is connected to measured signal. The idle level is high and the baud rate is 19.2 kb/s. The trigger mode is
synchronous rising edge. Please follow these steps: