FLUKE TIR4/FT-20 TiR4 60Hz Thermal Imaging Camera, 76800 Pixels 420 x 240

User Manual for the Fluke TiR4 60Hz Thermal Imaging Camera, 76800 Pixels 420 x 240 - Page 76

For TIR4/FT-20.

PDF File Manual, 132 pages, Read Online | Download pdf file

TIR4/FT-20 photo
Loading ...
Loading ...
Loading ...
TiR2,TiR3,TiR4,Ti40,Ti45,Ti50,Ti55
Users Manual
7-4
Using User-Defined Display Screen
Temperature Markers
Note
This feature is available on TiR2, TiR4, Ti45 and Ti55 models only.
In addition to basic display screen temperature markers (see Chapter 4), the IR-
FlexCam offers the following advanced marker options available in scan target
mode and/or on a saved image you open:
Up to three user-defined spot temperatures each marked with a crosshair.
Up to three user-defined area markers each indicated by a custom-sized
box.
To enable the user-defined spot temperature and area markers:
1. Assign the Marker toolbar visible function to a programmable button (see
Chapter 2).
2. From scan target mode or from an open image, tap the programmable
button; the Marker toolbar appears in the upper left corner of the display
screen.
To add spot temperature markers to the display screen from either scan target
mode or from an open image:
1. Use the mouse controller to position the pointer over the crosshair icon in
the Marker toolbar.
2. Tap E.
3. Use the mouse controller to position the mouse crosshair over the image
spot desired.
4. Tap E to place a spot temperature marker. The marker name, followed
by the temperature of that spot appears on the display screen.
5. Repeat Steps 3-4 to add up to two additional spot temperature markers.
6. Select the rectangle icon from the Marker toolbar to add area markers (see
the next set of procedures), or tap the programmable button to close the
Marker toolbar and return either to scan target mode or to the open image.
From an open image, tap
again to return to scan target mode.