Camera Overview
Camera Display Screen
2
2-9
Table 2-2. Display Screen – Descriptions (cont.)
Item Description
N
Center box with temperatures – Center 50 by 50 pixel box with the
maximum, average, and minimum temperatures in the box (when
enabled).
O
Hot cursor temperature – Temperature and location of the hottest
temperature in the image; always in red (when enabled).
P
Cold cursor temperature – Temperature and location of the coldest
temperature in the image; always in blue (when enabled).
Q
Analysis point – Temperature of marker point in the image. You can
add up to three marker points (when enabled).
R
Analysis area – Min., avg., and max. temperatures of the marker area
in the image. You can add up to three marker areas (when enabled).
S
Picture-in-picture (PIP) – The fused, or blended, infrared/visible light
image appears in the center quarter of the display screen and the
visible light image appears in the rest of the display screen (when
enabled).
T
IR-Fusion® blend level dialog box – Used to change the IR-Fusion®
blend level from full infrared (IR) to full visible light (VL) or some
combination in between. Disabled when using optional 10 and 54-mm
lenses.