Siglent SDS2352X-E oscilloscope

DSO programming guide - Page 198

For SDS2352X-E.

PDF File Manual, 256 pages, Read Online | Download pdf file

SDS2352X-E photo
Loading ...
Loading ...
Loading ...
Digital Oscilloscope Series
198
WGEN
WAVE_PARA? | WVPR?
Query
DESCRIPTION
The WAVE_PARA? query returns the
location, name, frequency, amplitude, and
offset of four arbitrary waveforms.
QUERY SYNTAX
WAVE_PARA? <index>
RESPONSE FORMAT
WAVE_PARA
POS,<index>,WVNM,<name>,FREQ,<freq
>,AMPL,<ampl>,OFST,<ofst>
EXAMPLE
For SDS2000X series, when the AWG
option is installed, the following query
returns the parameters of M0.
Query message:
WVPR? M0
Response message:
WVPR
POS,M0,WVNM,SINE,FREQ,1.000000e+0
3,AMPL,6.000000e+00,OFST,0.000000e+0
0
RELATED COMMANDS
STL?
Note:
See the table Availability of WGEN Commands in Each Oscilloscope Series for details.