REFERENCE
REF_DISPLAY | REFDS
Command /Query
DESCRIPTION
The REF_DISPLAY command enables or
disables the current reference channel
shown on the screen.
The REF_DISPLAY? query returns whether
the current reference channel shows on the
screen.
COMMAND SYNTAX
REF_ DISPLAY <state>
<state>:= {ON,OFF}
Note:
Only used when the current reference
channel has been stored, and the Reference
function is enable.
QUERY SYNTAX
REF_ DISPLAY?
RESPONSE FORMAT
REF_ DISPLAY <state>
EXAMPLE
The following command displays the
waveform of the current reference channel.
Command message:
REFDS ON
RELATED COMMANDS
REFCL
Note:
The table below shows the availability of command in each oscilloscope series.