![](https://files.manualsfile.com/26211658-bsir30/bgc.png)
12 (800) 449-8691
Electrical Requirements
This appliance requires a grounded dedicated circuit with the
following requirements:
240/208 VAC, 60Hz, 50 amp
Performance may be compromised if the electrical supply is
less than 240 volts.
For US models, the power cord is not included with the range.
If a power cord kit is used, it shall be rated 240V, 50 amps. It
must include three or four conductors with closed loop
terminals and be marked for use with ranges with nominal 1
3/8” (35mm) diameter connecon openings. A 4-conductor
cord is required for installaons where grounding through the
neutral is prohibited such as:
• New branch-circuit installaons (1996 NEC)
• Mobile homes
• Recreaonal vehicles
• In an area where local codes prohibit grounding through
the neutral.
For Canadian models, the power cord is included.
Cet appareil nécessite un circuit dédié, mis à la terre, avec les
exigences suivantes:
240/208 VAC, 60Hz, 50 amp
Les performances peuvent être compromises si l'alimentaon
électrique est inférieure à 240 volts.
Pour les modèles américains, le cordon d'alimentaon n'est
pas fourni avec la cuisinière. Si un kit de cordon d'alimentaon
est ulisé, il doit être spécié pour 240 V, 50 ampères. Il doit
comprendre trois ou quatre conducteurs avec des cosses à
boucle fermée et être marqué pour une ulisaon avec des
cuisinières ayant des ouvertures de connexion d'un diamètre
nominal de 1 3/8" (35 mm). Un cordon à 4 conducteurs est
nécessaire pour les installaons où la mise à la terre par le
neutre est interdite :
• Nouvelles installaons de circuits de dérivaon (NEC 1996)
• Mobile homes
• Véhicules de loisirs
• Dans une zone où les codes locaux interdisent la mise à la
terre par le neutre.
Pour les modèles canadiens, le cordon d'alimentaon est
inclus.
Exigences électriques