The multicast address can be configured to realize live view for more than the maximum number of cameras
through network.
A multicast address spans the Class-D IP range of 224.0.0.0 to 239.255.255.255. It is recommended to use the IP
address ranging from 239.252.0.0 to 239.255.255.255.
Steps:
1. Go to Configuration > Network > Advanced Settings > Other to enter the multicast address settings
interface.
Figure 5. 23 Multicast Address Settings
2. Enter the multicast address in the text filed.
3. Click Save to save the settings.
The device will reboot automatically to activate the multicast address settings.
5.3.10 Configuring Remote Alarm Host
Purpose:
With a remote alarm host configured, the device will send the alarm event or exception message to the host when
an alarm is triggered. The remote alarm host must have the CMS (Client Management System) software installed.
Steps:
1. Click Configuration > Network > Advanced Settings > Other to enter the alarm host settings interface.
Figure 5. 24 Remote Alarm Host
2. Enter Alarm Host IP and Alarm Host Port in the text fields.
The Alarm Host IP refers to the IP address of the remote PC on which the CMS (Client Management System)
software (e.g., iVMS-4200) is installed, and the Alarm Host Port must be the same as the alarm monitoring
port configured in the software (default port is 7200).
3. Click Save to save the settings.