APPLIANCE GAS CONNECTION
IMPORTANT: This appliance must be installed by an authorised person.
WARNING: DO NOT MODIFY THIS APPLIANCE
If the appliance cannot be adjusted to perform correctly, contact the service department.
This appliance utilises a threaded 1/2" gas male fitting.
To connect the appliance to the gas network with a flexible hose, a supplemental hose nipple fitting is
needed which is supplied with the appliance. (Fig. 07)
Gas inlet (mm) Nat gas Gas inlet (mm) LPG
From RH rear side: 35 mm From RH rear side: 35mm
Up from floor: 596 mm (model 90 and 120) Up from floor: 681 mm (model 90 and 120)
Up from floor: 617 mm (model 100 and 110) Up from floor: 702 mm (model 100 and 110)
Fig. 07
Gas Regulator
The gas connection is via 1/2" tapered thread. Connect the cooker to the gas supply and test for leaks.
NEVER use a naked flame to check for gas leaks.
Natural Gas: Gas regulator supplied with the appliance must be installed. ULPG: Test point adaptor to be
fitted and checked at time of installation.
Using a flexible connection
This appliance is approved for connection with a flexible hose, which complies with the AS/NZS 1869 (AGA
Approved), 10mm ID, class B or D, between 1-1.2m long. Connection shall be in compliance with AS/NZS
5601.
When installing the hose restraint device, the appliance anchor point is the rear panel.
Using a Copper Pipe connection
We recommend that the isolation valve be fitted prior to the cooker to enable isolation of the cooker from
the gas supply. The valve must be easily accessible at all times.
To find out the gas type factory settings, see label on the rear of the appliance.
Adaption to various types of gas
Burners Gas type Pressure (kPa) Injector
(
mm
)
Mj/hr By-pass size (mm)
Small Natural 1.00 0.92 4.20 0.34 re
ulated
Small ULPG 2.75 0.56 4.00 0.34
Medium Natural 1.00 1.17 6.60 0.36 re
g
ulated
Medium ULPG 2.75 0.73 6.90 0.36
Lar
g
e Natural 1.00 1.55 11.50 0.52 re
g
ulated
Lar
g
e ULPG 2.75 0.98 12.30 0.52
Wok 2way Natural 1.00
Ex. 2 x 1.14
int.0.80
15.60
Ext. 0.65 reg. int.
0.34 re
g
.
Wok 2way ULPG 2.75
Ex. 2 x 0,73
int. 0.50
17.00
Ext. 0.65
int. 0.34 re
g
.