CONVERSION TO DIFFERENT TYPES OF GAS
Before performing any maintenance operation, disconnect the appliance from the
gas supply and electricity network.
REPLACING THE NOZZLES TO OPERATE WITH ANOTHER TYPE OF GAS
When converting to ULPG remove the NG gas regulator (if fitted) and fit ULPG test
point adaptor.
If converting to Natural Gas, fit gas regulator
Follow the instructions below to change the burner nozzles on the work surface:
1) Pull out the plug from the electric outlet to avoid any type of electric contact.
2) Remove the grids from the work surface.
3) Remove the burners.
FIG 16
4) Unscrew the nozzles using a 7 mm spanner, and replace them with those needed
for the new type of gas according to what is indicated in the Energy Consumption
Table.
FIG 17
5) Burner "MINIMUM" adjustment:
Work surface burner adjustment: follow the instructions below to adjust the work
surface burner minimum:
Light the burner and set the knob to the MINIMUM position (small flame).
Remove the knob of the valve that is press fit on the rod of that valve.
For all burners except for the wok burner, insert a small slotted screwdriver
into the hole on the valve rod and turn the choke screw to the right or left until the
burner flame is adjusted to minimum.
The wok burner has 2 adjustment screws on either side of the body of the
valve. Screw A is for the outer ring and screw B is for the inner ring. Turn the choke
screw to the right or left until the burner flam e is adjusted to minimum.
Ensure sure that the flame does not go out when s witching quickly from the
MAXIMUM to the MINIMUM position.