WWW.SIGLENT.COM 84
E.g: :SOURce:CURRent:SET? CH1
Response: 2.000000\n
Obtain the measured current value
Command format: MEASure:CURRent? <channel>
Description: Get the current measurement value of the selected channel
E.g: MEASure:CURRent? CH1
Response:1.999407\n
Get power measurement
Command format: MEASure:POWER? <channel>
Description: Get the electrical power measurement value of the selected channel
E.g: MEASure:POWER? CH1
Response:19.959515\n
Get the running status of the channel
Command format: MEASure[:RUN]:MODE? <channel>
Description: Get the running status of the selected channel
E.g: MEASure:RUN:MODE? CH1
Response: CV\n
Configure Configuration Command Subsystem
Set OVP value
Command format: [:SOURce]:OVP <channel>,{<value> | MINimum | MAXimum |DEFault}
Description: Set the overvoltage value of the selected channel
E.g: :SOURce:OVP CH1,8
Description: Set the OVP value of CH1 channel to 8V
Command format: [:SOURce]:OVP? <channel>
Description: Get the overvoltage value of the selected channel
E.g: :SOURce:OVP? CH1
Response: 15.000000\n