bracket. The angle brackets are not sent with the command string.
Optional parameters are enclosed in square brackets ([ ]). If you do not specify a value
for the optional parameter, the instrument will use the default value. For example, the
[:SET] in the above command can be omitted (for example: ‘VOLT? CH1’), and the
command will operate on the current channel. The square brackets are not sent with the
command string.
Command Summary
1) IEEE Common Command Subsystem.
2) Measure Command Subsystem.
3) Configure Configuration Command Subsystem.
4) List Configuration Command Cubsystem.
5) System Configuration Command Subsystem.
Command Description
IEEE Common Command Subsystem
*IDN?
Command format: *IDN?
Description: Get device information string (return string content includes: manufacturer,
device model, device serial port number, software version number)
E.g: *IDN?
Response: Siglent Technologies,SPS5082X,SPS5X2006005,3.1.1.5\n
*RST
Command format: *RST
Description: Restore the state of the device to the initial state.