SPS5000X Series User Manual
WWW.SIGLENT.COM 56
When three power supplies are output in parallel, host A realizes the output control of
the entire parallel system. The maximum output current that can be set is three times the
rated current of the current model. The output voltage and current of host A are set to the
output voltage and current of the parallel system.
Parallel or Series among channels
Models with two or three output channels, support the combination series or parallel
output between the channels