In series, the output control of the entire series system is realized by the host A. The
maximum output voltage that can be set is twice the rated voltage of the current model.
The output voltage and current of the host A are set to be the output voltage and current
of the series system.
(2) Parallel between AB
Mode setting
Setting method: Menu 1.System 5.M/S mode settings to enter the
setting interface, press the knob to display a cursor, turn the knob to select the
configuration of the slave/slave mode, and press the knob to make the setting effective.
After power supply A enters the menu 5. M/S mode settings interface according to the
above setting method, select 2.Master/ Parallel1 option, power supply B enters the
setting interface according to the above method, and select 5. Slave/ Parallel option.
Setting interface
A
B