External Analog Control
Four working modes of voltage control voltage, voltage control current, resistance control
voltage, and resistance control current can be realized through the ports on the rear panel.
In the external voltage control mode, an adjustable voltage of 0-10 V is connected to the
input terminal to simulate the output from 0 to full-scale, to adjust the value of the voltage
and current output by the power supply (10 V corresponds to the voltage or current value of
the full-scale of the power supply).
External voltage control voltage output
Setting method: Menu 2.Configure 7.Voltage control , press the knob or
the Set button to enter the setting interface, then press the knob or the Set button
to enter the selection, and press the knob or turn the knob to select and then
press the knob or the Set button to confirm .
Load
DC
SPS5000X
+
-
Analog
connector
DC
V_PROG_
Voltage
0-10V
2 core shielded
wire or twisted pair
2
4
External voltage control voltage output
External resistance control voltage output:
The operation method is the same as (external voltage control voltage output), select
and confirm
Load
DC
SPS5000X
+
-
Analog
connector
R_PROG_
Voltage
0-10K
2 core shielded
wire or twisted pair
2
4
External resistance control voltage output