Hoshizaki F1002MAJ F-1002MAJ 22" Slim-Line Series Ice Machine

Service Manual - Page 68

For F1002MAJ.

PDF File Manual, 126 pages, Read Online | Download pdf file

F1002MAJ photo
Loading ...
Loading ...
Loading ...
68
5b. F-1501MWH-C
Specification Sheet
AC SUPPLY VOLTAGE 208-230/60/1 (3 wire with neutral)
COMPRESSOR 208-230 V 9.3 RLA 56 LRA
GEAR MOTOR 120 V 5.6 FLA 400W
CABINET FAN MOTOR 115 V 0.51FLA 8W
OTHER 120 V 0.03A
MAXIMUM FUSE SIZE 20 A
MAX. HACR BREAKER (USA ONLY) 20 A
MAX. CIRC. BREAKER (CANADA ONLY) 20 A
MINIMUM CIRCUIT AMPACITY 20 A
ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F
ELECTRIC W (kWH/100 lbs.) 1780 (3.95) 1796 (3.57)
POTABLE WATER 118 (12.0) 145 (12.0)
WATER-COOLED CONDENSER 719 (73.0) 472 (39.0)
gal./24HR (gal./100 lbs.)
SHAPE OF ICE Cubelet
ICE QUALITY Approx. 80%, Ice (90/70°F, Conductivity 200 µs/cm)
BIN CONTROL SYSTEM (PRIMARY) Photoelectric Sensor (BC1 (Infrared Sensor))
BIN CONTROL SYSTEM (SECONDARY) Proximity Switch (BC2 (Mechanical))
REFRIGERANT CHARGE R-404A, 1 lb.4oz. (575g)
Performance Data Sheet
APPROXIMATE
Ambient
ICE PRODUCTION Temp. °F (°C)
PER 24 HR. 70 (21) 1208 548
1211 549 1184 537
80 (26) 1158 525 1132 514 1107 502
90 (32) 1083 491 1096 497 1035 469
lbs./DAY kg/day
100 (38) 1012 459 990 449 928 421
APPROXIMATE ELECTRIC 70 (21) 1796 -- 1794 -- 1791 --
CONSUMPTION 80 (26) 1789 -- 1787 -- 1785 --
90 (32) 1782 -- 1780 -- 1786 --
watts 100 (38) 1791 -- 1797 -- 1802 --
APPROXIMATE WATER 70 (21) 617 2336 946 3579 1595 6038
CONSUMPTION PER 24 HR. 80 (26) 611 2313 936 3543 1586 6003
TOTAL 90 (32) 602 2279 932 3526 1577 5970
gal. / day l/day
100 (38) 594 2246 919 3478 1564 5921
EVAPORATOR OUTLET TEMP. 70 (21) 6 -15 6 -15 6 -15
°F (°C) 80 (26) 6 -15 6 -15 6 -15
90 (32) 6 -15 6 -15 6 -14
100 (38) 6 -14 6 -14 6 -14
HEAD PRESSURE 70 (21) 270 19.0 271 19.0 271 19.1
PSIG kg/sq.cmG
80 (26) 272 19.1 272 19.1 273 19.2
90 (32) 273 19.2 274 19.3 275 19.3
100 (38) 275 19.3 276 19.4 277 19.4
SUCTION PRESSURE 70 (21) 36 2.6 36 2.6 36 2.6
PSIG kg/sq.cmG
80 (26) 36 2.6 37 2.6 37 2.6
90 (32) 37 2.6 37 2.6 37 2.6
100 (38) 38 2.7 38 2.7 39 2.7
WATER FLOW FOR CONDENSER 33 gal/h (AT 100°F /WT 90°F)
PRESSURE DROP OF COOLING WATER LINE Less than 10 PSIG
HEAT OF REJECTION FROM CONDENSER 9500 BTU/h (AT 90°F/WT 70°F)
HEAT OF REJECTION FROM COMPRESSOR 1800 BTU/h (AT 90°F/WT 70°F)
Water Temp. °F (°C)
50 (10) 70 (21) 90 (32)
ENG.F-013.0.1196
Loading ...
Loading ...
Loading ...