63
3a. F-1001MRH
Specification Sheet
AC SUPPLY VOLTAGE 208-230/60/1 (3 wire with neutral)
COMPRESSOR 240 V 4.2 RLA 34 LRA
GEAR MOTOR 120 V 3 FLA 1/4 HP
FAN MOTOR REMOTE 120 V 3A MAX
OTHER 120 V 0.03A
MAXIMUM FUSE SIZE 15 A
MAX. HACR BREAKER (USA ONLY) 15 A
MAX. CIRC. BREAKER (CANADA ONLY) 15 A
MINIMUM CIRCUIT AMPACITY 15 A
ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F
ELECTRIC W (kWH/100 lbs.) 1520 (5.60) 1570 (4.1)
WATER gal./24HR (gal./100 lbs.) 89 (12) 111(12)
SHAPE OF ICE Flake
ICE HARDNESS Approx. 70%, Ice (32/21 (90/70), Conductivity 200 µs/cm)
BIN CONTROL SYSTEM Proximity Switch (BC (Mechanical))
CONDENSER Air-cooled Remote Condenser unit URC-5F Recommended
TOTAL REFRIGERANT CHARGE R-404A, 4 lb. 1 oz. (1850g)
(Ice Maker: 2 lb. 3 oz., Cond. Unit: 1 lb. 14 oz. )
Performance Data Shee
t
APPROXIMATE Ambient
ICE PRODUCTION Temp. °F (°C)
PER 24 HR. 70 (21) 930 422 895 407 865 393
80 (26) 835 379 805 366 780 353
90 (32) 750 341 745 338 700 317
lbs./DAY ( kg/day) 100 (38) 675 306 650 296 605 274
APPROXIMATE ELECTRIC 70 (21) 1285 -- 1285 -- 1290 --
CONSUMPTION 80 (26) 1290 -- 1290 -- 1290 --
90 (32) 1295 -- 1295 -- 1305 --
watts 100 (38) 1310 -- 1320 -- 1325 --
APPROXIMATE WATER 70 (21) 112 422 108 407 104 393
CONSUMPTION PER 24 HR. 80 (26) 100 379 97 366 93 353
90 (32) 90 341 89 338 84 317
gal. / day (l/day) 100 (38) 81 306 78 296 73 274
EVAPORATOR OUTLET TEMP. 70 (21) 23 -5 24 -4 25 -4
°F (°C) 80 (26) 25 -4 26 -3 26 -3
90 (32) 26 -3 27 -3 28 -2
100 (38) 28 -2 28 -2 28 -2
HEAD PRESSURE 70 (21) 221 15.5 221 15.5 221 15.5
PSIG (kg/sq.cmG) 80 (26) 239 16.8 239 16.8 239 16.8
90 (32) 256 18.0 256 18.0 256 18.0
100 (38) 295 20.7 295 20.7 295 20.7
SUCTION PRESSURE 70 (21) 33 2.3 33 2.3 33 2.3
PSIG (kg/sq.cmG) 80 (26) 35 2.4 35 2.4 35 2.4
90 (32) 36 2.5 36 2.5 36 2.5
100 (38) 39 2.7 39 2.7 39 2.7
CONDENSER VOLUME 74.5 cu in
HEAT OF REJECTION FROM CONDENSER 7660 BTU/h (AT 90°F /WT 70°F)
HEAT OF REJECTION FROM COMPRESSOR 1380 BTU/h (AT 90°F /WT 70°F)
50 (10) 70 (21) 90 (32)
Water Temp. °F (°C)
ENG.F-013.0.1196