AC SUPPLY VOLTAGE 208-230/60/1 (3 wire with neutral)
4.2 RLA 34 LRA 5.9 RLA 46 LRA
GEAR MOTOR 120 V 3 FLA 1/4 HP
OTHER 120 V 0.03A
MAXIMUM FUSE SIZE 15 A
MAX. HACR BREAKER (USA ONLY) 15 A
MAX. CIRC. BREAKER (CANADA ONLY) 15 A
MINIMUM CIRCUIT AMPACITY 15 A
ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F
ELECTRIC W (kWH/100 lbs.) 1248 (4.24) 1245 (3.1)
POTABLE WATER 91 (12) 107 (12)
WATER-COOLED CONDENSER 480 (66) 303 (34)
gal./24HR (gal./100 lbs.)
SHAPE OF ICE Flake
ICE HARDNESS Approx. 70%, Ice (32/21 (90/70), Conductivity 200 µs/cm)
BIN CONTROL SYSTEM Proximity Switch (BC (Mechanical))
REFRIGERANT CHARGE R-404A
Performance Data Shee
t
APPROXIMATE Ambient
ICE PRODUCTION Temp. °F (°C)
PER 24 HR. 70 (21) 890 404 855 389 840 380
80 (26) 820 372 805 364 785 356
90 (32) 770 349 755 342 735 334
lbs./DAY ( kg/day) 100 (38) 720 327 705 320 655 297
APPROXIMATE ELECTRIC 70 (21) 1155 -- 1160 -- 1185 --
CONSUMPTION 80 (26) 1155 -- 1160 -- 1185 --
90 (32) 1155 -- 1160 -- 1185 --
watts 100 (38) 1155 -- 1160 -- 1185 --
APPROXIMATE WATER 70 (21) 410 1.86
526 2.39 811 3.69
CONSUMPTION PER 24 HR. 80 (26) 427 1.94 548 2.49 853 3.88
90 (32) 443 2.01 571 2.59 898 4.08
gal. / day (l/day) 100 (38) 461 2.09 599 2.72 989 4.49
EVAPORATOR OUTLET TEMP. 70 (21) 23 -5 23 -5 25 -4
°F (°C) 80 (26) 23 -5 23 -5 25 -4
90 (32) 23 -5 23 -5 25 -4
100 (38) 23 -5 23 -5 25 -4
HEAD PRESSURE 70 (21) 263 18.5 266 18.7 269 18.9
PSIG (kg/sq.cmG) 80 (26) 263 18.5 266 18.7 269 18.9
90 (32) 263 18.5 266 18.7 269 18.9
100 (38) 263 18.5 266 18.7 269 18.9
SUCTION PRESSURE 70 (21) 33 2.3 34 2.4 35 2.5
PSIG (kg/sq.cmG) 80 (26) 33 2.3 34 2.4 35 2.5
90 (32) 33 2.3 34 2.4 35 2.5
100 (38) 33 2.3 34 2.4 35 2.5
WATER FLOW FOR CONDENSER 38 gal/h (AT 100°F /WT 90°F)
PRESSURE DROP OF COOLING WATER LINE Less than 7 PSIG
HEAT OF REJECTION FROM CONDENSER 7110 BTU/h (AT 90°F /WT 70°F)
HEAT OF REJECTION FROM COMPRESSOR 1340 BTU/h (AT 90°F /WT 70°F)
50 (10) 70 (21) 90 (32)
Water Temp. °F (°C)
COMPRESSOR 240 V
Aux. Code C-1
and Earlier
Aux. Code C-2
and Later
15 oz. (425g) 12.3 oz. (349g)
ENG.F-013.0.1196