2. BC1 (Infrared Sensor) Shutdown Delay (S1 dip switch 1, 2, 3)
Infrared sensor shutdown delay is the delay between the infrared sensor detecting ice
(infrared sensor yellow LED ashing or steady) and the start of the shutdown sequence.
For dispenser unit applications, the ice level at shutoff may need to be adjusted
depending on the dispenser agitation or dispense method. Increasing the shutdown
delay setting allows for a higher level of ice in the bin before the icemaker shuts down.
For a typical dispenser unit application, a 100-sec. shutdown delay is recommended.
When used with a standard Hoshizaki ice storage bin, any shutdown delay setting is
acceptable. WARNING!Increasing the shutdown delay allows a higher level of ice
in the dispenser unit/ice storage bin before shutdown. This could lead to icemaker
movement or ice overow.
S1 Dip Switch Setting
Infrared Sensor Shutdown Delay
No. 1 No. 2 No. 3
OFF OFF OFF 0 Seconds
ON OFF OFF 100 Seconds (1.6 minutes) (Factory Default)
OFF ON OFF 1100 Seconds (18.3 minutes)
OFF OFF ON 1650 Seconds (27.5 minutes)
ON ON OFF 2200 Seconds (36.7 minutes)
OFF ON ON 0 Seconds
ON ON ON 0 Seconds
3. Drain Frequency Control (S1 dip switch 4)
This unit is factory set for optimum performance with the 1-in-1 drain cycle (S1 dip
switch 4 in the off position). This setting allows for removal of sediment from the
evaporator without interrupting the icemaking process. An optional 1-in-12 drain cycle is
available.
S1 Dip Switch Setting
Drain Timer Interval Drain Valve Open
No. 4
OFF (1-in-1) 1 Hour 2 Seconds
ON (1-in-12) 11 Hours 45 Minutes 10 Minutes
4. Continuous Dispensing Timer (S1 dip switch 5 & 6)
DCM models only. The dispense mode switch on DCMs must be in the "CONTINUOUS"
position for this setting to apply. The factory setting allows ice to be dispensed
continuously as long as the dispense solenoid is activated.
S1 Dip Switch Setting
Dispense Time
No. 5 No. 6
OFF OFF No Limit
ON OFF 20 Seconds
OFF ON 60 Seconds
ON ON No Limit