Kolpak KF8-0812-FR Walk-In Freezer 8'-6.25" H, 7'-9" W, 11'-7" L with Era floor

Installation operation - Page 7

For KF8-0812-FR.

PDF File Manual, 37 pages, Read Online | Download pdf file

KF8-0812-FR photo
Loading ...
Loading ...
Loading ...
www.kolpak.com 800-225-9916 7
If the installation area is not level, find the high point of this perimeter line. The
floor, floor screed and wall must be leveled to this point.
Use a 4’ level to determine floor levelness. Be sure to check both directions for
floor levelness.
Cam Action Panel Fasteners
Before starting to assemble the unit, be sure to familiarize yourself with the operation of
the panel fasteners.
To operate the cam locks, insert a 5/16” hex wrench (packed in hardware box)
through the access hole in the panel interior skin, and into the hex opening in the
fastener. Turn the wrench clockwise approximately 3/4 of a turn to put the cam
hook into the locked position.
If a problem should occur, such as having to unlock a panel that was not properly
positioned, you must turn the handle counterclockwise until it stops, in order to
reset the cam position.