www.kolpak.com 800-225-9916 28
Membrane Roof System
Locate the parts required for the installation of the membrane roof. The membrane roof
is shipped rolled and folded. The termination bar and any roof trim required are shipped
in 6” diameter by 10’ long cardboard tubes. A hardware box containing screws,
fastening plates and sealant is also included.
Check the roof of the walk-in unit and remove any foreign matter. Seal all
protruding rough edges and screw heads, rivets, etc. with tape or sealant. This
will prevent any chance of penetrating or wearing a hole in the membrane roof
cap.
WARNING
Make sure that all safety precautions are taken as necessary to prevent anyone working
on the roofing installation from falling off from the top of the unit.
Ceiling panels are not intended for walking traffic or any other loads. Ensure that during
install, a lift or boom is used to support installers and equipment weight, so that the
extra loads are not supported by the ceiling panels.
CAUTION
Make sure that any debris is removed from the top of the unit before installing any
roofing materials, as damage may occur to the membrane roof cap if installed over a
sharp object.