19.10.4 Ambient Temperature Compensation:
A high ambient temperature or restricted condenser air flow will have a negative effect on ice
production. The high side thermistor placed on the liquid line directly reacts to changes in
system temperatures due to changing ambient conditions. To compensate, the main power
board is programmed to add or subtract to the production time for every 1°F ambient
temperature change sensed at the condenser location.