Marvel ML15WSG2LB 15 Inch Black Wine Cooler

User Manual - Page 161

For ML15WSG2LB.

PDF File Manual, 288 pages, Read Online | Download pdf file

ML15WSG2LB photo
Loading ...
Loading ...
Loading ...
156
Section 17: Outdoor Models
17.1: Operation
Dynamic cooling utilizing a forced air condenser and interior circulation fans moves air
effectively and efficiently. The Prime control system brings the control interface display
inboard where it will not be affected by the elements of the outdoors. The main control
board is located in the machine compartment. It is shielded by a mylar curtain behind
the compartment access cover, this also protects from the elements of the outdoors.
The entire cabinet and door are wrapped with a stainless finish.
17.2: Characteristics / Differences
Outdoor appliances are typically identified by the stainless steel wrapped cabinet and
matching stainless door. The control is located in the interior of the appliance.
In addition, the rear access panel in the machine compartment has a mylar curtain
installed along the top edge to prevent water or moisture from entering.
17.3: Fans
Fan function and location is not unlike the indoor Marvel and Marvel Pro models. Air is
drawn across the evaporator plate from the supply louvers and outward into the interior
cabinet through the circulation fan. The blades rotate in a clockwise direction as you
face the hub.
NOTE: As of mid-August 2015, a rear fan guard was added to the fan assemblies on the
outdoor beverage center and beverage dispenser models. The fan guard is to eliminate the
possibility of wires getting caught in the fan blade from behind the coil cover.
The approximate serial number range is 20150824xxxH. This is an approximate date and some
variation may be seen in the field.
An exploded view on the following page shows the assembly drawing of the coil cover
components along with both the front and rear fan guards.
Evaporator Fan
Loading ...
Loading ...
Loading ...