Marvel ML15WSG2LB 15 Inch Black Wine Cooler

User Manual - Page 174

For ML15WSG2LB.

PDF File Manual, 288 pages, Read Online | Download pdf file

ML15WSG2LB photo
Loading ...
Loading ...
Loading ...
169
Section 18: Prime Control
18.1: Control Type
The prime control still utilizes the top mounted control housing as seen in the picture below.
It is the same basic control as the previously used Micro Sentry controls; however the control is
reduced considerably in depth and appears identical to the control used in the previous door
mounted versions in the Marvel Scientific models and the current Outdoor Models.
The control system is driven by a NTC thermistor, located on the mid cabinet sidewall and
defrosted by a similar thermistor attached to the upper left hand evaporator plate (Refer to
section 6).
The control housing assembly consists of the control, display light button, and the door
activated light rocker switch.
Excluding model options, the cabinet design, mechanical operation, and air flow are identical to
that mentioned in section 3 of this manual. The main difference seen between the Prime and
Aurora control systems is that of the control system itself. There is no variation cabinet and
defrost thermistor function between the two control model types.
Light Rocker Switch Door activated
Loading ...
Loading ...
Loading ...