APPLIANCE GAS CONNECTION
IMPORTANT: This appliance must be installed by an authorised person.
WARNING: DO NOT MODIFY THIS APPLIANCE
If the appliance cannot be adjusted to perform correctly, contact the service department.
This appliance utilises a threaded 1/2" gas male fitting.
To connect the appliance to the gas network with a flexible hose, a supplemental hose nipple fitting is needed which is
supplied with the appliance. (Fig. 07)
Gas inlet positions with different leg heights – mm
Gas inlet (mm) - Nat gas Gas inlet (mm) – ULPG
From RH rear side: 70 mm From RH rear side: 70mm
Up from floor cooker with worktop stamped: 655 - 725mm Up from floor cooker with worktop stamped: 570 - 640mm
Up from floor cooker with worktop welded: 675 - 745mm Up from floor cooker with worktop welded: 590 - 660mm
Gas Regulator
The gas connection is via 1/2" tapered thread. Connect the cooker to the gas supply and test for leaks. NEVER use a naked
flame to check for gas leaks.
Natural Gas: Gas regulator supplied with the appliance must be installed.
ULPG: Test point adaptor to be fitted and checked at time of installation.
Using a flexible connection
This appliance is approved for connection with a flexible hose, which complies with the AS/NZS 1869 (AGA
Approved), 10mm ID, class B or D, between 1-1.2m long. Connection shall be in compliance with AS5601.
When installing the hose restraint device, the appliance anchor point is the rear panel
.
Fig. 07