Part number 550-100-211/0122
– 17 –
220 /29 9/3 00 /39 9 
 (continued)

1. Follow the same instructions as LP conversion, except using
the correct Natural gas conversion kit, See Figure8,page12 .
2. If LP gas was already selected in the boiler control, the gas
type parameter will need to be adjusted. In the contractor
menu, under the Boiler Settings menu, adjust the “LP Gas
setting to “NO.
3. Turn throttle screw clockwise until it stops, and then turn
counter-clockwise number of turns per Figure19. Figure19
is intended to make rough adjustment to gas valve to allow
the boiler to re. ey are NOT intended to replace proper
adjustment of combustion valves per instructions on page91
of this manual.
4. Adjust the oset regulating screw in a Clockwise direction
the number of turns listed in Figure19, according to the
boiler model/size.
Thedoormustbeinplaceduringopera-
tion.
DO NOT operate the boiler with the
jacket door removed except for inspection and
testing as directed in this manual.
Figure19 Course adjustment settings—Throttle and
offset adjustments to be made prior to rst
ignition, by size.
Boiler
Model
ThrottleTurns
(Counterclockwise Q from
Bottom-out Position)
OffsetTurns
(Clockwise P
Factory LP Position )
EVG 220NG
1-5/8 3/8
EVG 299/300
NG
3-3/4 1/8
EVG 399NG
3 1/8
Figure18 Installer conversion label
Loading ...
Loading ...
Loading ...