INSTALLATION
4-Wire Connection
3-Wire Connection
INSTALLATION
3-WIRE CONNECTION (GROUNDED NEUTRAL) - U.S.A. ONLY
Grounding through the neutral conductor is prohibited for new branch-circuit
installations (1996 NEC); mobile homes; and recreational vehicles, or in an
area where local codes prohibit grounding through the neutral conductor. For
installations where grounding through the neutral conductor is prohibited, see the
Ungrounded Neutral graphic.
Use grounding terminal or lead to ground unit. Connect neutral terminal or lead
to branch circuit neutral in usual manner.
Failure to do so could result in death, fire or electric shock.
3-WIRE CABLE FROM HOME POWER SUPPLY
Use the 3-wire cable from home power supply where local codes permit a
3-wire connection.
1. Disconnect power.
2. Connect the two black wires B together using a UL listed wire connector.
3. Connect the two neutral (white) wires C and the ground (green or bare) wire d
(of the oven cable) using a UL listed wire connector.
4. Connect the two red wires G together using a UL listed wire connector.
5. Install junction box cover.
4-WIRE CONNECTION (UNGROUNDED NEUTRAL) - U.S.A. AND CANADA
4-WIRE CABLE FROM HOME POWER SUPPLY
Use the 4-wire cable from home power supply in the U.S. where local codes
do not allow grounding through neutral, New Branch circuit installations
(1996 NEC), mobile homes and recreational vehicles, new construction and
in Canada.
1. Disconnect power.
2. Connect the 2 black wires B together using a UL listed wire connector.
3. Connect the 2 red wires C together using a UL listed wire connector.
4. Untwist white wire from green (or bare) ground wire coming from the oven.
5. Connect the 2 neutral (white) wires H together using a UL listed wire connector.
6. Connect the ground (green or bare) wire FA from the oven cable to the ground
(green or bare) wire (in the junction box) using a UL listed wire connector.
7. Install junction box cover.
qualied technician. Ask your dealer to recommend a qualied
technician or an authorized repair service.
the exible conduit from the oven to the junction box using a UL
Route the exible electrical supply conduit from the oven to
Failure to do so could result in death, re or electric shock.
Grounded Neutral
E
I
G
H
F
A
B
C
D
I
Ungrounded Neutral
B
C
D
G
F
E
H
A
the oven and contact a qualied technician.
WARNING
A. Junction Box
B. Black Wires
C. Neutral (White) Wires
D. Ground (Green or Bare) Wire
E. Cable from Oven
F. UL Listed Conduit Connector
G. Red Wires
H. UL Listed Wire Connectors
I. House Electrical Supply
Grounded Neutral
Ungrounded Neutral
WARNING
A. Junction Box
B. Black Wires
C. Red Wires
D. Cable from Oven
E. UL Listed or CSA Approved
Conduit Connector
F. Ground (Green or Bare) Wires
G. UL Listed Wire Connector
H. Neutral (White) Wires
I. House Electrical Supply