9
Fig. 9-3 Optional door w/ tank tray & louvers
Cylinder & regulator/hose assembly
protected by heatshield
Additional adapters may be required
for your setup (not included)
Equipped with
adapter for hose
assembly.
Flex connector
not included.
Fig. 9-2 Additional ventilation opening for L.P. cylinder
RHP DOOR MEETS ALL REQUIREMENTS ABOVE
Access
door
L.P.
cylinder
Ventilation
opening
(at cylinder gas
connection level,
min. 10 sq. in
free area)
(L.P. Cylinder setups only)
Louvers
Tray
ENCLOSURE
The countertop MUST be constructed of non-
combustible materials. The enclosure can be
constructed of combustible or non-combustible
materials.
Access to the interior of the enclosure is required for
ease of installation and service.
For combustible enclosures, an insulating liner is
always required (see Table 1).
WHEN A PROPANE (L.P.) CYLINDER IS USED IN
THE ENCLOSURE
When a propane (L.P.) cylinder is installed inside of the
enclosure, the additional guidelines below MUST be
followed. FAILURE TO DO SO MAY CAUSE DAMAGE
TO YOUR UNIT AND/OR PERSONAL INJURY. Refer to
Fig. 9-1 and 9-2.
Only a C.S.A. listed stainless steel flex connector must
be connected to the unit.
The regulator/hose assembly coming from the cylinder
must only be connected to the above mentioned
flex connector. A
1
/2" male-to-male flare adapter will
be required (not included). DO NOT connect the
regulator/hose assembly directly to the unit.
A non-combustible heatshield must be installed to
protect the regulator/hose assembly and cylinder valve.
The cylinder must rest at least 2" above the ground.
An additional vent opening is recommended in
the access door near the cylinder and at the gas
connection level (minimum 10 sq. in. of free area).
RHP offers an "access door with tank tray and louvers"
which includes a heatshield that rests directly above
the L.P. cylinder, a tray, and louvers to meet the cylinder
install requirements. The door is shown in Fig. 9-3.
Contact your dealer for ordering information.
3" min.
Grill
C.S.A. listed
stainless steel
flex connector
Non-combustible
Heatshield
Regulator/
hose
assembly
L.P.
cylinder
2" min.
from ground
Fig. 9-1 L.P cylinder orientation
1
/2" male-to-male
flare adapter
(not included)
GRILL ENCLOSURE / VENTILATION REQUIREMENTS (cont.)