REMOTE CONTROL
Precaution: The Remote Controller will not operate properly if strong light strikes the sensor window ofthe air
conditioner or if there are obstacles between the Remote Controller and the air conditioner,
AUTO SWING
• PresstheairflowdirectioncontrolbuttonfortheverticalIouver'stoswingautomatically,
ON/OFF TIMER
- STOPPINGOPERATION
• Ever/timeyoupushthisbutton,whenthe setisoperating,timerissetasfollows.
(1Hour_2Hours_ 3Hours- 4Hours-5Hcers_ 6Hours--_7Hours-8Hours-9Hours-*
10Hours-11Hours-12Hours-Cancel)
TheSettingTemperaturewillberaisedby2°F 30rain.laterandby2°F after
another30 min.
- STARTINGOPERATION
• Everytimeyoupushthis button,whenthesetisnotoperating,timer isset
asfollow.(1Hour-2Hours- 3Hours-4Hours-5Hours-6Hours-_7Hours
8Hours-,9Hours_ 10Hours_ 11Hours--12Hours--Cancel)
ENERGY SAVER
Thefanstopswhenthecompressorstopscooling,
•Approximatelyevery3 minutesthe fanwillturnonandchecktheroom
airtodetermineifcoolingisneeded.
COOL/FAN
• Everytimeyoupushthis button,itwilltogglebetweenCOOLandFAN.
POWER
•To turntheSetON,pushthebutton.Totumthe SetOFF,pushthe buttonagain.
Thisbuttontakespriorityoveranyotherbuttons.
Whenyoufirstturniton,theSetisonthe Highcoolmodeandthe temp.at72°F
TEMPERATURE SEI"rlNG
• Thisbuttoncanautomaticallycontrolthetemperatureofthe room.
The temperaturecanbesetwithina rangeof60°Fto86°F byI°F.
Selectthelowernumberforlowertemperatureofthe room.
FAN SPEED
• Everytimeyoupushthisbuttonitissetasfollows.(High---Low---High..,)
POWER
FAN
SPEED
1.4 SAFETY PRECAUTIONS
1. When servicing, set the ROTARY SWITCH to
Off ( O ) and unplug the power cord.
2. Observe the original lead dress.
If a short circuit is found, replace all parts which
have been overheated or damaged by the short
circuit.
3. After servicing, make an insulation resistance test
to prevent the customer from being exposed to
shock hazards.
1.5 INSULATION RESISTANCE TEST
1. Unplug the power cord and connect a jumper
between 2 pins (black and white).
2. The grounding conductor (green or green and yel-
low) isto be open.
3. Measure the resistance value with an ohm meter
between the jumpered lead and each exposed
metallic part on the equipment at all position
[except Off ( 0 )] of the ROTARY SWITCH.
4. The value should be over 1 M_.