1. PREFACE
This service manual provides various service information, including the mechanical and electrical parts, etc.
This room air conditioner was manufactured and assembled under a strict quality control system.
The refrigerant is charged at the factory. Be sure to read the safety precautions prior to servicing the unit.
1.1 FEATURES
• DESIGNED FOR COOLING ONLY
• POWERFUL AND INCREDIBLE COOLING
• THE SIMPLE INSTALLATION AND SERVICE
• BUILT-IN ADJUSTABLE THERMOSTAT
• WASHABLE ONE-TOUCH FILTER
• COMPACT SIZE
1.2 SPECIFICATIONS
__ MODELS
ITEMS
POWER SUPPLY
COOLING CAPACITY
INPUT(W)
RUNNING CURRENT(A)
EER(Btu/hW)
OPERATION INDOOR('C)
CONDITION OUTDOOR('C)
REFRIGERANT(R-22) CHARGE
EVAPORATOR
CONDENSER
FAN,INDOOR
FAN,OUTDOOR
FANSPEEDS, FAN/COOLING
OPERATIONCONTROL
ROOM TEMP CONTROL
AIR DIRECTION CONTROL
79053 79056 79074 79122
5,100
565
5.2
9
7.8
2R * 10C
1R * 14C
2/2
R/St_T_
THERMOSTAT
STRUCTURE TOP-DOWN
PROTECTOR COMPRESSOR
FAN MOTOR
POWER CORD
DRAIN SYSTEM
1(_, 115V,
5,400
540
4.8
10
11.1
2R * 10C
2R * 14C
60Hz
7,000
760
7
9.2
26.6(DB) *
35(DR) *
12.4
2R * 14C
2R * 16C
12,000
1,260
11.5
9.5
19.4(WB) *
23.9(WB) *
17
2R * 13C
2R * 17C
79184 79188
10, 208/-230V, 60Hz
17,500/18,000
1,940/ 2,000
9.6/9.0
26.1
3R "15C
2R "19C
BLOWER
PROPELLER TYPE FAN WITH SLINGER-RING
2/2 2/2 2/3 2/3
P,B/_)]Ecokr'_OL RISWlTCH R/SWITCH R_'WlTCH
11"IE_ISTOB _IEEV_3_rAT THE!_'TAT _AT
VERTICAL LOUVER(RIGHT & LEFT)
HORIZONTAL LOUVER(UP & DOWN)
SUDE IN - OUT CHASSIS
OVERLOAD PROTECTOR
INTERNAL THERMAL PROTECTOR
3 WIRES WITH GROUNDING
ATTACHMENT PLUG(CORD - CONNECTED TYPE)
DRAIN PIPE OR SLAPLSHED BY FAN SLINGER
2/2
REMOTECON]t_OL
]HER_ISTOR
* DB = DRY BULB TEMP. * WB = WET BULB TEMP.
• NOTE: Specifications are subject to minor change without notice for further improvement.