58
3. Start RFID Calibration.
Using the LCD Menu:
Go to the RFID menu.
Select Interface RFID Tag Calibration Do RFID
Calibrate, and select the icon.
Note
For more information, see section 6.5.5 RFID (Radio Frequency Identification) Settings.
Using the RFIDDETECT command:
Note
For more information, see the FBPL Command Reference Manual on your model's
Manuals page at support.brother.com
.
4. Depending on the tag type and tag length, the calibration can take several minutes. At the
end of calibration either a green or red screen appears. The green screen appears when
the calibration is successful and the red one when it is not.
5. If calibration fails, select the or icon to clear the error. In most cases when this
error occurs, it is necessary to reposition the Antenna Slide. In some cases, it may be due
to an incompatibility between the tag and the reader. After the calibration is complete, select
the or icon to continue and save the RFID calibration values.