9 Technical data
9 Technical data
Dimensions SMS 55 SMS 55
Extra height
EURO 60 EURO 60
Extra height
EURO 60 WP
Appliance height (incl.
slide plate 3mm)
762mm 827mm 762mm 827mm
Appliance height (incl.
adjustable plinth)
848–893mm 783–828mm 848–893mm 866–911mm
Appliance width 546mm 546mm 596mm 596 mm 596mm
Appliance depth 572mm 572mm 572mm 572 mm 572mm
Appliance weight 42–48kg 63kg
Plumbing in Electrical connection
Cold or hot water up to 60 °C: G¾" See identification plate:
Open the appliance door.
Identification plate is located on
left-hand side on edge of tub.
Permitted pressure of water sup-
ply:
0.1–1.0MPa
(1–10bar)
Max. pumping height: 1.2m
Ambient conditions
Minimum ambient temperature: +10°C
Safety concept
Provided power is going to the appliance, the electronic control unit monitors the appliance.
Any malfunctions are indicated by error messages.
Overflow protection
The overflow protection system does not work in the event of a power failure. Turn
off the water tap during longer periods without operation.
The electronic control unit monitors the water level in the appliance. In the event of a malfunc-
tion, the drain pump turns on, stopping the supply of water to the appliance.