7. Inside the storage bin, disconnect the sucon tube by
squeezing the tabs and pulling the tube clear. See Fig. 24.
Allow the water tank to drain.
8. Reconnect the sucon tube as illustrated. See Fig. 25. Make
sure the tabs lock into place; a loose ng may cause a
water leak.
9. Remove the ice produced, then clean the storage bin liner,
door liner, and door gasket using a neutral cleaner. Rinse
thoroughly aer cleaning.
10. Move the control switch to the “ICE” posion to start the
automac ice making process.
11. To conrm bin control operaon, hold ice in contact with
the bin control thermostat bulb. If the icemaker does not
stop within 10 seconds, the bin control thermostat must be
adjusted. Installaons at higher altude locaons are more
likely to require adjustment.
Sucon Tube
Tabs
Water Tank
Drain
Fig. 24
Sucon Tube
Tabs
Fig. 25
MAINTENANCE
The appliance must be maintained in accordance with the
instrucon manual and labels provided with the appliance.
Consult with your local Perlick Cered Service Representave
about maintenance service. To obtain the name and phone
number of your local Perlick Cered Service Representave,
visit www.perlick.com.
Only qualied service technicians should
service the appliance.
Failure to install, operate, and maintain the
equipment in accordance with this manual will adversely
aect safety, performance, component life, and warranty
coverage.
To reduce the risk of electric shock, do not
touch the control switch or plug with damp hands. Make sure
the control switch is in the “OFF” posion before plugging in
or unplugging the appliance.
Move the control switch to the “OFF”
posion and unplug the appliance from the electrical outlet
before servicing.
CHOKING HAZARD: Ensure all components,
fasteners, and thumbscrews are securely in place aer any
maintenance is done to the appliance. Make sure that none
have fallen into the storage bin.
Do not place ngers or any other objects
into the ice discharge opening.
Aer service, make sure that there are no
wires pinched between the panels and appliance. Make sure
you do not damage or pinch the water supply line, drain line,
or power cord.
DANGER
!
DANGER
!
DANGER
!
DANGER
!
DANGER
!
DANGER
!
DANGER
!
Loading ...
Loading ...
Loading ...