PERLICK RESIDENTIAL ICE MAKER MANUAL
WATER SUPPLY AND DRAIN CONNECTIONS
A plumbing permit and services of a licensed plumber may be
required in some areas.
A water supply line shut-o valve and drain valve must be
installed.
Be sure there is sucient extra water supply line and drain line
for the appliance to be pulled out for service.
Drain line should not be piped directly to the sewer system.
Water line installaon to the appliance is not
warranted by Perlick.
Water-hammer issues must be resolved
by a qualied plumber before installing the appliance. Water
hammer can cause appliance damage that may lead to water
leakage or ooding.
A minimum of 1/2” nominal ID hard pipe
or equivalent is required for the drain line. Installing a smaller
diameter drain line will reduce water ow and may lead to
water leakage or ooding.
If using the oponal drain pump (63802A),
test its operaon every me the appliance is cleaned and
sanized. See “IV.E. Oponal Drain Pump 63802A” for details. If
the oponal drain pump is not operang properly, water could
back up and overow, leading to costly water damage.
Usually an electrical permit and services of a licensed electrician
are required.
The maximum allowable voltage variaon is ±10 percent of the
nameplate rang.
For oponal drain pump (63802A) installaon, refer to the
instrucons included with the pump.
WATER SUPPLY AND DRAIN
CONNECTIONS
Water supply and drain connecons must
be installed in accordance with applicable naonal, state, and
local regulaons.
Normal operang water temperature must be
within 45°F to 95°F (7°C to 35°C). Operaon of the appliance,
for extended periods, outside of this normal temperature range
may aect appliance performance.
Water supply pressure must be a minimum
of 10 PSIG and a maximum of 113 PSIG. If the pressure exceeds
113 PSIG, the use of a pressure reducing valve is required.
External lters, strainers, or soeners may be
required depending on water quality. Contact your local Perlick
Cered Service Representave or local Perlick distributor for
recommendaons.
Connect to potable water supply only. Do not
connect to a hot-water supply.
In areas where water damage is a concern,
install in a contained area with a oor drain.
WARNING
DANGER
!
WARNING
WARNING
WARNING
WARNING
Water Supply Inlet Minimum Water Supply Line Size Drain Outlet Minimum Drain Line Size
1/2" Female Pipe Thread (FPT) 1/4" Nominal ID Copper
Water Tubing or Equivalent
1/2" Female Pipe Thread (FPT) 1/2" Nominal ID
Hard Pipe or Equivalent
WARNING
WARNING
WARNING
WARNING
Fig. 23
Piping to approved drain. Leave a 2-inch (5-cm)
vercal air gap between the end of the pipe and
the drain.
2-inch (5-cm)
air gap
Floor
Drain
Shut-O Valve
Drain Valve
Water Supply Inlet
1/2" FPT
Drain Outlet
1/2" FPT
Vented Tee Connecon
Be sure there is sucient extra water supply line
and drain line for the appliance to be pulled out
for service.