38 Servicing Your Honda
Subframe
4. Connect the negative (–) terminal (10) to the
battery (11).
5. Connect the air cleaner connecting tube (12) to
the air cleaner box (13) and tighten the air
cleaner connecting tube clamp screw (14) so
the distance between the clamp ends is 0.30 ±
0.06 in (7.5 ± 1.5 mm).
6. Connect the breather tube (15) and IAT sensor
connector (16).
7. Connect the starter/ignition relay connector
(17) and install the seat support base (18).
8. Install and tighten the collars (19), washers
(20)
and seat support
base mounting bolts (21)
to the specified torque:
7 lbf·ft (10 N·m, 1.0 kgf·m)
9. Install the left and right mufflers (page 115).
10. Install the seat (page 33).
(10) negative (–) terminal
(11) battery
(11)
(10)
(12) air cleaner connecting tube
(13) air cleaner box
(14) air cleaner connecting tube clamp screw
(15) breather tube
(16) IAT sensor connector
(15)
(14)
(12)
0.30 ± 0.06 in (7.5 ± 1.5 mm)
(14)
(16) (13)
(17) starter/ignition relay connector
(18) seat support base
(19)
collars
(20) wa
shers
(21) seat support base mounting bolts
(19)(20)(21)
(18)
(17)
(19)(20)(21)