Entrapment Protection 13
INSTALL THE LIFTMASTER MONITORED ENTRAPMENT PROTECTION (LMEP)
DEVICES (OPTIONAL)
Always refer to the installation instructions that are included with your LiftMaster Entrapment Protection (LMEP) Devices. Without an
LMEP properly installed, the operator will only work with constant pressure to close mode of operation.
WIRE THE LIFTMASTER MONITORED ENTRAPMENT PROTECTION (LMEP)
DEVICES
Connect the LiftMaster Monitored Entrapment Protection
(LMEP) Device to the logic board according to the models
shown below:
1
White (Blue)
White/Black (Brown)
MODELS CPS-U, CPS-UN4,
CPS-RPEN4, CPS-OPEN4
MONITORED PHOTOELECTRIC
SENSOR
MONITORED
EDGE SENSOR
White
White
White
Black
Black
Black
4-Wire Sensing Edge
2-Wire Monitored Sensing Edge
Red
Red
CPS-MEI
CPS-EI
NOTE: Only one LMEP Device can be connected to the logic board. To attach additional LMEP’s, the CPS3CARD option card is required.
Secondary (non-monitored) entrapment protection devices (with N.O. dry contact) will be wired to the EDGE and COMMON terminals.
LiftMaster
CPS-MEI