User Manual LiftMaster 50-CP4 Sensing Probe Single Piece

LiftMaster 50-CP4 Sensing Probe Single Piece - Use Manual - Use Guide PDF.
Documents: Go to download!
User Manual
  • Owner's manual - (English)
Specification


User manual Sensing Probe Single Piece

SERIAL NUMBER

There is a barcode serial number on the bottom of "puck" and on the product box. When calling to talk about your product, please have this number handy.

TRENCH PIPE & CABLE

CONDUIT & SLIP JOINT

After pulling cable through plastic conduit, insert conduit inside slip joint on "puck."

DO NOT GLUE (to un-install later, if needed).

CONNECT TO GATE

CP-4 works with all gate operators-powered or solar, single or dual free exit terminals.

TEST SENSITIVITY

NOTE: IN MOST CASES DO NOT ADJUST SENSITIVITY OR REMOVE LID.

BURY CONDUIT & “ PUCK”

Test unit with gate by swinging steel over puck (or driving vehicle by). If it opens the gate correctly, finish installation by burying conduit and puck 3-5" below surface.

OTHER INSTRUCTIONS

* CP-4 may be installed above ground by screwing "puck" directly to an immovable post or building

* If installed above ground, use conduit to mechanically protect cable (animals will eat)

* Car should be going at least S MPH at sensor to be detected

Install CP-4 at least:

6-10 feet away from buried power, telephone, or invisible dog fence

10 feet away from natural gas lines

20 feet away from power pole with a transformer

100 feet back from railroad traffic

200 feet away from high power substation power lines

80-100 feet back from gate operator

Technical Specifications

Power Required8-24 VAC or 8-30 VDC
Stand-By Current30-70 Microamps (mA)
Alarm Current30-40 Milliamps (mA)
Relay Time2-3 seconds
Relay ContactsSPDT, floating, N.O. or N.C ( From C)
Relay Contacts Rating

1 amp/24 VDC

(1 mA at 5 VDC min. load)

Enclosure RatingIP67
Strength Rating

9.53 ton-force

8646 kgf

Temperature Range

-25oF. - +140oF.

-32oC. - -60oC.

Dimensions4.5 in. dia. x 2.5 in. high
Weight5 lbs. with 100 ft. cabe

RETURNING MERCHANDISE

CONSUMER: Contact your installer

INSTALLER: CALL BEFORE DIGGING UP

Call (717) 532-0033, option 1 to troubleshoot and receive a Return Merchandise Authorization (R.M.A.) number. Write R.M.A. number on return shipping box and any correspondence included with defective product.

DISTRIBUTOR: Send installers directly to Cartel I, using 717-532-0033, option 1 as phone number.

5 YEAR WARRANTY

All Cartell products are warranted against defects in material and workmanship for five years. This warranty does not cover defects caused by, but not limited to: acts of God, improper installation, abuse, fire damage, electrical surges, integrated system failures, improper lid/gasket installation, and damage to cable (if applicable) caused by slicing, pulling, tangling, improper splicing or not running in non-metalic conduit.

CONTACT INFORMATION

TECH SUPPORT

717-532-0033, option 1

RMA's

717-532-0033, option 1

SHIPPING

717-532-0033, option 2

ACCOUNTING

717-532-0033, option 3

INSIDE SALES

717-532-0033, option 4

EMAIL

[email protected]

ORDERING (Distributors only)

[email protected]

ADDRESS

510 West King Street Shippensburg, PA 17257



See other models: CSW200UL PPLV1-10 PPK3M LJ8900W EL1SS

LiftMaster 50-CP4 | File type: PDF | Filename: 77150250_50-cp4.pdf | Size: 754.32 KB | Language: English

Download User Manual

Specs Sheet

  • Power Supply: 8-24 VAC oe 8-30 CSX
  • Voltage: 30-70uA
  • Cable Lead Length: 100 ft.

Product Infomation and Reviews - 50-CP4 photo

50 CP4 Photo

T: @manualsFile

https://manualsFile.com

LiftMaster 50-CP4 Questions and Answers


#1 What is the warranty of this product?
Accessory Warranty: 5 Years

#2 How many voltage?
Standby Current: 30-70uA; Alarm Current: 30 to 40mA