Part Number: 000015430 Rev 02 5/20 91
E02 LONG HARVEST
Harvest time exceeds 7 minutes for 3 consecutive harvest
cycles.
Possible Cause Checklist
Improper Installation
Refer to “Installation/Visual Inspection Checklist” on
page 108
Water System
Water area (evaporator) dirty
Dirty/defective water dump valve
Vent tube not installed on water outlet drain
Water freezing behind evaporator
Plastic extrusions and gaskets not securely mounted to
the evaporator
Clogged water distribution tube
Electrical System
Ice thickness probe out of adjustment
Bin switch closed/defective
Premature harvest - The control board initiates a
harvest cycle when the high water level probe circuit is
complete and the low water level probe is open.
Refrigeration System
Non-Manitowoc components
Improper refrigerant charge
Defective head pressure control valve
Defective harvest valve
TXV flooding (check bulb mounting)
Defective fan cycling control
Water cooled only - Water regulating valve is
incorrectly adjusted or will not close during harvest
cycle.