Part Number: 000015430 Rev 02 5/20 89
E01 LONG FREEZE
Freeze time exceeds 35 minutes for 3 consecutive freeze
cycles.
Possible cause checklist
Improper Installation
Refer to “Installation/Visual Inspection Checklist” on
page 108
Water System
Dirty/defective water level probe
Low water pressure (20 psig min.)
High water pressure (80 psig max.)
High water temperature (90°F/32.2°C max.)
Clogged water distribution tube
Dirty/defective water fill valve
Dirty/defective water dump valve
Defective water pump
Loss of water from sump area
Electrical System
Low incoming voltage
Ice thickness probe out of adjustment
Harvest cycle not initiated electrically
Contactor not energizing
Compressor electrically non-operational
Defective fan cycling control
Defective fan motor
Miscellaneous
Non-Manitowoc components
Improper refrigerant charge
Defective head pressure control
Defective harvest valve
Defective compressor