Installation/Visual Inspection Checklist
Inadequate Clearances
Check all clearances on sides, back and top. Reference
“Clearance Requirements” on page 26
Ice machine is not level
Level the ice machine
Condenser is dirty
Clean the condenser
Water filtration is plugged (if used)
Install a new water filter
Water drains are not run separately and/or are not
vented
Run and vent drains according to the Installation
Manual
Floor drain must have an air gap
Install condensation drain in the ice machine base
Line set is improperly installed
Reinstall according to the Installation Manual
Reference “Location of Ice Machine” on page 25