152 Part Number: 000015430 Rev 02 5/20
Ice Thickness Check
The ice thickness probe is factory-set to maintain the ice
bridge thickness at 1/8" (3 mm).
NOTE: Initial gap should be set with the ice machine off.
Verify the water curtain/splash shields are in place when
performing this check. It prevents water from splashing
out of the water trough. Remove the curtain to make
an adjustment, then replace immediately after the
adjustment is made.
1. Inspect the bridge connecting the cubes. It should be
about 1/8" (3 mm) thick.
2. If adjustment is necessary, turn the ice thickness
probe adjustment screw clockwise to increase bridge
thickness or counterclockwise to decrease bridge
thickness. Set a 9/32" gap between the ice thickness
probe and evaporator as a starting point. Then adjust
to achieve 1/8" ice thickness.
3. Make sure the ice thickness probe wire and the
bracket do not restrict movement of the probe.
Place 9/32" (7 mm) Drill Bit
Here To Set Initial Gap
1/8" (3 mm)
Ice Bridge Thickness
Adjusting
Screw
ICE THICKNESS ADJUSTMENT