Part Number: 000015430 Rev 02 5/20 103
Discharge Line Temperature
Record freeze cycle discharge line
temperature at the end of the
freeze cycle.
T2 _________°F (°C)
Reference “Discharge Line
Temperature Analysis” on page
123
Discharge line temp.
150°F (65°C)
or higher at the end of
the freeze cycle
Discharge line temp.
150°F (65°C)
or higher at the end of
the freeze cycle
Discharge line temp.
less than
150°F (65°C) at the end
of the freeze cycle
Discharge line temp.
150°F (65°C) or higher
at the end of the freeze
cycle
Wait 5 minutes into the freeze
cycle.
Compare temperatures of
compressor discharge line and
harvest valve inlet.
Reference “Harvest Valve
Analysis” on page 121
The harvest valve inlet
is Hot
-and-
approaches the
temperature of a Hot
compressor discharge
line.
The harvest valve inlet
is Cool enough to hold
hand on
-and-
the compressor
discharge line is Hot.
The harvest valve inlet
is Cool enough to hold
hand on
-and-
the compressor
discharge line is Cool
enough to hold hand on.
The harvest valve inlet
is Cool enough to hold
hand on
-and-
the compressor
discharge line is Hot.
Loading ...
Loading ...