User Manual - Page 185

For IRT1900N263E.

Loading ...
Loading ...
Loading ...
Part Number: 000015430 Rev 02 5/20 185
7. Make sure that all of the vapor in the charging hoses
is drawn into the ice machine before disconnecting
the charging hoses.
A. Run the ice machine in freeze cycle.
B. Remove the high side low loss fitting from the
liquid line filter drier.
C. Open the high and low side valves on the
manifold gauge set. Any refrigerant in the lines
will be pulled into the low side of the system.
D. Allow the pressures to equalize while the ice
machine is in the freeze cycle.
E. Remove the hoses from the ice machine and
install the caps.
Loading ...
Loading ...
Loading ...