Care and Maintenance (cont.)
1. Shut o the heater, including the pilot. Allow the heater to cool for at least 30 minutes.
2. Inspect the burner, pilot, and primary air inlet holes on the orice holder for dirt and debris (see Fig. 45).
3. Blow air through the ports/slots and holes in the burner.
4. Check the orice holder again, which is located at the end of the burner tube. With a cloth or vacuum
cleaner nozzle, remove any large particles of dust, dirt, or other debris.
5. Blow air into the primary air holes on the orice holder.
6. Repeat steps 3 and 4. Clumps of dust/debris may have been pushed into the burner.
Clean the pilot assembly. A yellow tip on the pilot ame indicates dust and dirt in the pilot assembly. A small
pilot air inlet hole is about 2" from where the pilot ame comes out of the pilot assembly (see Fig. 46). Ensure
the heater is o, and lightly blow air through the air inlet hole. If you do not have compressed air, blowing
through a drinking straw will also work.
LOG SET
If you remove the log set for cleaning, refer to page 20 for placement instructions.
Replace the log set if it is broken or chipped (dime-sized or larger).
Fig. 46—Pilot Air Inlet Hole
Fig. 45—Primary Air Inlet Slot on Burner Tube
Label all wires prior to disconnection when servicing controls. Wiring errors can cause
improper and dangerous operation.
CAUTION
If any of the original wire as supplied with the appliance must be replaced, it must be replaced with a wire of
at least a temperature rating.
Verify proper operation after servicing.
Air Inlet Hole
LP/Propane
Primary Air Inlet Slot
Primary Air Inlet Slot
Natural Gas
Burner Tube Burner Tube