Remington REM-L180ANT-F 18-in 30000-BTU Dual-Burner Vent-Free Gas Fireplace Logs with Thermostat

User Manual - Page 23

For REM-L180ANT-F.

PDF File Manual, 40 pages, Read Online | Download pdf file

REM-L180ANT-F photo
Loading ...
Loading ...
Loading ...
©2017 Pinnacle Climate Technologies 23 Vent-Free Gas Log Heater User Manual
LIGHTING INSTRUCTIONS
1. STOP! Read all the above safety information before proceeding.
NOTE: When used as a vented decorative appliance, use of the
thermostat function is prohibited—operate manually only.
2. Turn the control knob clockwise to the “OFF” position
(see Fig. 26).
3. Wait ve (5) minutes to clear out any gas. Then smell for gas,
including near the oor. If you smell gas, STOP! Follow “B” in
the safety information above. If you don’t smell gas, go to the
next step.
4. Turn the control knob counterclockwise to the “PILOT”
position. Depress control knob.
5. With control knob depressed, push down on the ignitor button
until the pilot lights. The pilot is located behind the heater
screen near the rear of the burner (see Fig. 27).
Do not attempt to light the pilot by hand.
6. Keep the control knob depressed for (30) seconds after the
pilot lights. Then release the control knob.
If the control knob does not pop up when released, stop and
immediately call a qualied service technician or gas supplier.
If the pilot goes out, repeat steps 3 through 7. Wait (1) minute
before attempting to light pilot again. If after several tries the pi-
lot still goes out, turn the gas control knob clockwise to
the “OFF” position and call a qualied service technician.
7. Turn the control knob counterclockwise to the desired
setting.
Operation—REM-L180ALT-F / REM-L180ANT-F / REM-L240ALT-F / REM-L240ANT-F
Fig. 26—Control Knob
Fig. 27—Pilot
TO TURN OFF GAS TO THE HEATER
1. Turn the control knob clockwise to the “OFF” position.
Shutting O the Burner Only (Pilot Stays Lit):
1. Turn the control knob clockwise to the “PILOT position.
THERMOSTATIC CONTROL OPERATION
The thermostatic control valve on this heater is dierent from standard thermostats. Standard thermostats simply
turn the burner on and o. The thermostat sensing bulb on the control valve used on this heater senses changes
in room temperature and varies the ame accordingly. The burner will shut o completely when the room
temperature exceeds the set temperature. When the room temperature drops below the set temperature, the
unit will cycle back on. The control knob can be set to the desired comfort level between 1 and 5.
The replace screen must be in place while the heater is in operation.
WARNING
Any glass doors must be completely opened while the heater is operating.
WARNING
Loading ...
Loading ...
Loading ...