Remington REM-L180ANT-F 18-in 30000-BTU Dual-Burner Vent-Free Gas Fireplace Logs with Thermostat

User Manual - Page 14

For REM-L180ANT-F.

PDF File Manual, 40 pages, Read Online | Download pdf file

REM-L180ANT-F photo
Loading ...
Loading ...
Loading ...
©2017 Pinnacle Climate Technologies 14 Vent-Free Gas Log Heater User Manual
FLOOR CLEARANCES
In addition to meeting noncombustible material clearances, you must also meet required clearances between
replace opening and mantel shelf. A replace hood must be used if you do not meet the below clearances.
A. If installing the heater on oor level, you must maintain the minimum distance of 5" to combustibles (see
Fig. 7).
B. If combustible materials are less than 5" to the replace, you must install the heater at least 5" above the
combustible ooring (see Fig. 8).
Installation (cont.)
Combustible
Material
Non-Combustible
Material
5"
Min.
Fig. 7—Minimum Fireplace
Clearances if Installed at Floor Level
Combustible
Material
Hearth
5 in.
Min.
Fig. 8—Minimum Fireplace
Clearances above Combustible Flooring
Damper
Damper Clamp
Damper
“Opened
Position
Fig. 9—Attach Damper to Fireplace
INSTALLING DAMPER CLAMP ACCESSORY FOR VENTED OPERATION
NOTE: When used as a vented heater, the heater must be installed only in a solid-fuel burning replace
with a working ue constructed of noncombustible material. You may use this heater as a vented product.
When used as a vented decorative appliance, use of the thermostat function is prohibited—operate
manually only. There are three reasons for operating your heater as a vented model:
1. The replace does not meet the clearance requirements for vent-free operation.
2. State or local codes do not permit vent-free operation.
3. You prefer vented operation.