©2017 Pinnacle Climate Technologies 13 Vent-Free Gas Log Heater User Manual
MANTEL CLEARANCES
In addition to meeting noncombustible material clearances, you must also meet required clearances between
the replace opening and mantel shelf. A replace hood is required if the below clearances are not met.
Determining Mantel Clearances:
If you meet the minimum clearance requirements between the mantel shelf and the top of the replace
opening, you do not require a replace hood (see Fig. 5).
Determining Minimum Mantel Clearance When Using a Hood:
If the minimum clearances in Fig. 6 are not met, you must use a hood. When using a hood there are still
certain minimum mantel clearances required, as shown in Fig. 6.
NOTICE: When operating the heater, the surface temperature of adjacent walls and mantels become hot. Walls
and mantels above the rebox may become too hot to touch. If installed properly, these temperatures meet
the requirement of the national product standard. Follow all minimum clearances shown in this manual.
NOTICE: If your installation does not meet the minimum clearances, you must only operate the heater with
the ue damper open, or you must raise the mantel to an adequate height.
Installation (cont.)
Noncombustible Material Installation Requirements
Noncombustible
Material Distance
Requirements for Safe Installation
8" or more Noncombustible material is okay.
Less than 8"
Noncombustible material must be extended to at least 8". See between 8" and
12" on the previous page. If you cannot extend the material, the heater must be
operated with the ue damper open.
Maximum
10"
Combustible
Mantel
Minimum 20"
Maximum
10"
C
Mantel
Minimum
18"
Minimum
10"
Maximum
2.5"
4" Sheet
Metal Hood
Fig. 5—Closed Flue Mantel
Clearances without Hood
Fig. 6—Closed Flue Mantel
Clearances with Hood