Care and Maintenance
BURNER FLAME PATTERN
Figure 43 shows a correct burner ame pattern. Figure 44 shows an incorrect burner ame pattern.
The incorrect burner ame pattern shows sporadic, irregular ame tipping. The ame should not be dark
or have an orange/reddish tinge. NOTE: When using the heater the rst time, the ame will be orange for
approximately one hour until the log cures. If the burner ame pattern is incorrect, as shown in Figure 44, do
the following:
Turn the heater o (see TO TURN OFF GAS TO THE HEATER, page 22/23).
See the TROUBLESHOOTING GUIDE, page 33.
BURNER ORIFICE HOLDER AND PILOT AIR INLET HOLE
The primary air inlet holes allow the right amount of air to mix with the gas, which creates a clean burning
ame. Keep these holes clear of lint, dirt, dust, pet hair, and other debris. Before every heating season, clean
these holes—blocked air holes create soot. During operation, the heater should be cleaned at least every
three (3) months. A qualied service person should inspect the heater yearly.
Keep the burner tube and pilot assembly clean and free of dirt and other debris. Use compressed air of 30 PSI
or less to clean these parts. If using compressed air in a can, follow the directions on the can exactly. You may
damage the pilot assembly if the directions are not followed exactly.
FOR VENTED APPLICATIONS
Periodic examination and cleaning of the venting system and the solid fuel-burning replace, including
frequency of such examination and cleaning, must be done by a qualied agency.
Fig. 43—Correct Burner Flame Pattern Fig. 44—Incorrect Burner Flame Pattern
Turn o the heater and let cool before servicing.
WARNING
Failure to keep the primary air opening(s) of the burner(s) clean may result in sooting
and property damage.
WARNING
You must keep the control areas, burner, and circulating air passageways of the heater
clean. Inspect these areas before using the heater. Have a qualied service person
inspect the heater every year. Excessive lint from carpeting, bedding material, pet hair, etc. may require
that the heater be cleaned more frequently.