202
Press GEN1 Setup or GEN2 Setup
for generator 1 or generator 2,
respectively.
Press Waveform from the bottom
menu.
Select the waveform from the side menu.
Sweep Waves
Sine, square, ramp.
2. Press the Sweep from the bottom
menu.
3. From the side menu, turn Sweep
on.
Type of Sweep
4. Press Type to set the sweep to
linear or logarithmic.
Type
Linear, Log
Start and Stop
Frequency
5. Press the Start or Stop soft-keys to
set the start and stop frequency,
respectively.
Start/Stop
25MHz ~ 0.1Hz
Note
To configure a up sweeping, set the start frequency at a
lower value than the stop frequency. To configure a
down sweeping, set the start frequency at a higher
value than the stop frequency.
Center Frequency
& Span
Alternatively the center frequency and span can be
set instead of the start and stop frequencies.